Navonik Innovation / Resources
High-Rise Site Quality Checklist Kit
Free 23-page fillable PDF with 15 site quality checklists and 120 inspection prompts plus editable CSV logs for high-rise RCC sites. Approved project drawings, specifications and the responsible engineer set acceptance; the kit records what was checked and the evidence.
Get the free checklist kit (short request form; download unlocks once your request is saved).
Who it is for
Site engineers, builders, architects, PMC teams and government site inspectors on multi-storey RCC buildings.
The 15 checklists
- 01 Daily high-rise site verification — 8 points. When: Each working shift and after a significant change. Owner: Site engineer / QA engineer.
- 02 Survey and setting-out readiness — 8 points. When: Before setting out and before each floor grid transfer. Owner: Surveyor / site engineer.
- 03 Excavation and foundation readiness — 8 points. When: Before excavation changes and before foundation concrete. Owner: Site engineer / geotechnical and temporary works specialists.
- 04 Reinforcement inspection — 8 points. When: Before concrete conceals reinforcement. Owner: Site engineer / QA engineer.
- 05 Formwork, shoring and reshoring — 8 points. When: Before placement, after alteration and before removal. Owner: Temporary works supervisor / responsible engineer.
- 06 Slab and beam pre-pour release — 8 points. When: Immediately before slab/beam concrete placement. Owner: Site engineer / QA engineer / authorised release signatory.
- 07 Column, wall and core pre-pour — 8 points. When: Before column, shear wall and core wall placement. Owner: Site engineer / QA engineer.
- 08 Concrete delivery and placement — 8 points. When: For each relevant delivery and during the pour. Owner: Pour supervisor / QA engineer / testing technician.
- 09 Concrete sampling and test records — 8 points. When: At sampling and whenever results are received. Owner: Testing technician / QA engineer.
- 10 Slab finishing and curing readiness — 8 points. When: As finishing progresses and before the surface is left unattended. Owner: Pour supervisor / QA engineer.
- 11 Daily curing and early-age protection — 8 points. When: During every shift throughout the specified curing period. Owner: Curing supervisor / site engineer.
- 12 MEP openings and embedded items — 8 points. When: Before concrete and before cutting or drilling. Owner: MEP coordinator / site engineer / structural designer.
- 13 Masonry, plaster and finishes — 8 points. When: Before concealment and at agreed inspection stages. Owner: Site engineer / QA engineer.
- 14 Wet areas and waterproofing — 8 points. When: Before membrane concealment and after specified tests. Owner: Site engineer / waterproofing specialist.
- 15 Defects, close-out and handover — 8 points. When: During inspections and before area/project handover. Owner: QA engineer / project manager / responsible designer.
Sample: 06 Slab and beam pre-pour release
Release rule: Do not start placement until the identified hold items are closed and release is signed.
| ID | Topic | Check | Evidence |
|---|
| 06-01 | Documents | Confirm latest structural, architectural and MEP drawings and closed RFIs for the pour zone. | Drawing revision / RFI register |
| 06-02 | Survey and formwork | Verify grid, levels, member dimensions, thickness and temporary works release. | Survey / formwork release |
| 06-03 | Reinforcement | Confirm bottom/top bars, supports, anchorage, links and cover inspection is complete. | Reinforcement release |
| 06-04 | Openings | Verify sleeves, block-outs, conduits and edge details against approved coordinated drawings. | MEP / opening inspection |
| 06-05 | Joints | Confirm construction joint location, preparation and waterstop detail where required. | Approved joint detail |
| 06-06 | Cleanliness | Remove debris and standing contamination; confirm access for placing and vibration. | Final workfront inspection |
| 06-07 | Resources | Confirm approved mix, delivery plan, test crew, backup vibration/power and weather controls. | Pour plan / test plan |
| 06-08 | Curing and sign-off | Confirm curing materials and crew are ready; record release authority and time. | Curing readiness / signed pour card |
Status choices
Not checked, Checked, Issue, N/A. Checked means inspected against the project requirement; it is not a structural approval.
This kit supports record keeping. It does not certify structural safety or replace design, temporary works or statutory approvals.